AFP-200 Notifier Manual - Download User Guide | ShukMart

afp-200 notifier manual

The AFP-200 Notifier is a compact, intelligent fire alarm control panel designed for cost-effectiveness and versatility. It offers advanced features and supports up to 198 individually addressed points, making it ideal for a wide range of applications. This system combines powerful functionality with modular design, providing a reliable solution for fire safety needs.

1.1 Overview of the AFP-200 Fire Alarm Control Panel

The AFP-200 is a compact, intelligent fire alarm control panel offering advanced features and modular design. It supports up to 198 individually addressed points, making it suitable for various applications. Designed for cost-effectiveness, it combines a single-loop system with powerful capabilities, providing a reliable and versatile solution for fire safety and alarm management needs.

1.2 Key Features and Benefits

The AFP-200 Notifier offers a compact, modular design with advanced features like individual point identification and powerful capabilities. It supports up to 198 points, making it ideal for small to medium-sized applications. Its cost-effective design provides scalability and ease of use, ensuring reliable fire safety management with minimal installation and maintenance efforts required.

Types of Manuals Available

The AFP-200 Notifier provides three essential manuals: the Installation Manual, Instruction Manual, and Programming Manual. These resources guide users through setup, operation, and customization.

2.1 Installation Manual

The Installation Manual for the AFP-200 provides step-by-step instructions for proper setup. It covers hardware requirements, wiring guidelines, and mounting procedures, ensuring a secure and efficient installation process. The manual also includes troubleshooting tips to address common issues during setup, making it an essential guide for installers.

2.2 Instruction Manual

The Instruction Manual for the AFP-200 provides detailed guidance on system operation, features, and daily use. It explains how to navigate the control panel, configure settings, and utilize advanced functionalities. This manual is essential for understanding the system’s capabilities and ensuring optimal performance in various fire safety scenarios.

2.3 Programming Manual

The Programming Manual provides step-by-step guidance for configuring the AFP-200 system, including detector sensitivity, output circuits, and the Rapid Poll Algorithm. It details how to customize settings and troubleshoot configurations, ensuring optimal system performance and compliance with safety standards. This manual is essential for advanced users and technicians to maximize the system’s functionality and efficiency.

Installation Guide

The AFP-200 Notifier installation guide provides detailed instructions for setting up the control panel, ensuring proper system configuration and functionality. It covers essential steps and requirements.

3.1 Pre-Installation Requirements

Before installing the AFP-200 Notifier, ensure the site meets power supply, wiring, and environmental conditions; Verify compatibility with existing systems and prepare necessary tools and materials. Proper planning prevents installation issues and ensures compliance with safety standards and manufacturer guidelines.

3.2 Step-by-Step Installation Process

Start by unpacking and verifying all components. Mount the control panel securely, ensuring proper alignment. Connect the power supply and wiring according to the manual’s specifications. Install detectors and modules, following the system’s configuration. Test all circuits and connections to ensure functionality. Finally, perform a system test to confirm everything operates correctly before finalizing the installation.

3.3 Power Supply and Wiring Requirements

The AFP-200 requires 120 VAC, 50/60 Hz, 3.0 A, while the AFP-200E needs 220/240 VAC, 50/60 Hz, 1.5 A. Use a minimum 14 AWG wire with 600 VAC rating. Ensure proper grounding to avoid noise interference. Follow wiring diagrams in the manual to prevent voltage drops and ensure compliance with local electrical codes for safe installation.

Programming the AFP-200

Programming the AFP-200 involves configuring detection sensitivity, setting up output circuits, and utilizing the Rapid Poll Algorithm for efficient system operation and response.

4.1 Configuring Detection Sensitivity

Configuring detection sensitivity on the AFP-200 involves adjusting settings to optimize smoke and heat detection. Use the Notifier software or manual to set thresholds, ensuring accurate alarm triggers. Proper calibration enhances system reliability and reduces false alarms. Refer to the Instruction Manual for detailed steps and guidelines.

4.2 Setting Up Output Circuits

Setting up output circuits on the AFP-200 involves configuring alarm, trouble, and supervisory signals. Each circuit can be programmed for specific functions, such as activating horns, strobes, or remote devices. The system allows customization of output types and timing to meet application requirements. Refer to the Programming Manual for detailed setup instructions and circuit configuration options.

4.3 Understanding the Rapid Poll Algorithm

The Rapid Poll Algorithm enhances communication speed and system reliability. It ensures quick response times, typically under 2 seconds, for manual stations and other connected devices. This feature supports operation with untwisted, unshielded wire up to 1,000 feet, making it ideal for large-scale installations while maintaining data integrity and reducing installation complexity.

Features and Functionalities

The AFP-200 offers advanced features like output circuits, remote silence/reset/evacuate, and time control with holiday exceptions. Its robust design ensures adaptability, scalability, and reliable performance for fire safety systems.

5.1 Output Circuits and Their Functions

The AFP-200 features multiple output circuits that control various devices such as alarms, strobes, and relays. These circuits are programmable, allowing customization for specific applications. They ensure proper activation of safety devices during emergencies, enhancing system reliability and response efficiency. Each circuit can be configured to meet unique installation requirements, providing flexibility and adaptability.

5.2 Remote Silence/Reset/Evacuate Capabilities

The AFP-200 supports remote control of critical functions via monitor modules; Users can silence alarms, reset the system, or initiate evacuations remotely. This capability enhances response efficiency and system management, ensuring quick actions during emergencies without physical access to the control panel, thereby improving safety and operational flexibility.

5.3 Time Control Functions and Holiday Exceptions

The AFP-200 features advanced time control functions, enabling users to schedule system operations and set holiday exceptions. This allows for tailored fire safety management, ensuring alarms and notifications align with specific time frames or special events. The system supports temporary overrides, providing flexibility without compromising safety.

Troubleshooting and Maintenance

The AFP-200 Notifier includes diagnostic tools for identifying and resolving common issues. Regular maintenance ensures optimal performance, with procedures for resetting the panel and updating software.

6.1 Common Issues and Solutions

Common issues with the AFP-200 Notifier include alarm conditions, trouble signals, and communication faults. Solutions involve resetting the panel, checking wiring, and updating software. Regular maintenance and adherence to troubleshooting guidelines ensure system reliability and compliance with safety standards.

6.2 Resetting the Control Panel

To reset the AFP-200 Notifier, press and hold the SYSTEM RESET switch until the alarm condition clears. This action restores default settings and ensures proper system operation. Regular resets help maintain functionality and prevent false alarms, ensuring reliable fire safety monitoring and response capabilities.

6.3 Updating Software and Firmware

Update the AFP-200 Notifier’s software and firmware using Notifier’s PK-1 release 2.0 or terminal emulation software. Follow the instructions in the programming manual to ensure proper installation. Regular updates maintain system performance and compliance, preventing potential issues and ensuring all features function optimally for reliable fire safety monitoring and response.

Technical Specifications

The AFP-200 requires 120 VAC, 50/60 Hz, 3.0 A, while the AFP-200E requires 220/240 VAC, 50/60 Hz, 1.5 A. Wire size should be minimum 14 AWG with 600 VAC rating for reliable operation.

7.1 Power Requirements and Wire Size

The AFP-200 requires 120 VAC, 50/60 Hz, 3.0 A, while the AFP-200E requires 220/240 VAC, 50/60 Hz, 1.5 A. The recommended wire size is minimum 14 AWG with a 600 VAC rating for optimal performance and safety. Proper wiring ensures reliable operation and compliance with electrical standards.

7.2 Compatibility with Other Systems

The AFP-200 Notifier is designed to integrate seamlessly with Notifier’s range of fire safety systems and third-party devices. It supports standard communication protocols, ensuring compatibility with existing infrastructure. The modular design allows for easy integration with additional components, making it a versatile solution for comprehensive fire alarm networks and system expansions.

7.3 Environmental Operating Conditions

The AFP-200 Notifier operates effectively in environments with temperatures between 32°F and 120°F (0°C to 49°C) and relative humidity up to 93%. To ensure optimal performance, avoid exposing the panel to extreme temperatures, moisture, or corrosive environments, which may compromise its functionality and longevity.

Compliance and Safety Standards

The AFP-200 Notifier complies with UL 864 and NFPA 72 standards, ensuring reliability and safety in fire alarm systems. Adhere to installation guidelines and safety precautions to prevent hazards and maintain compliance.

8.1 Industry Certifications

The AFP-200 Notifier holds certifications from UL (Underwriters Laboratories) and meets NFPA 72 standards. These certifications ensure the system’s reliability and compliance with industry safety requirements. Regular updates and adherence to maintenance protocols further ensure ongoing certification and optimal performance in fire safety applications.

8.2 Safety Precautions During Installation

Always disconnect power before starting installation. Follow the manual’s instructions to avoid damage. Wear appropriate PPE, including gloves and safety glasses. Ensure proper grounding and wiring to prevent electrical hazards. Never work on live circuits. Verify all components are compatible and installed correctly to maintain system reliability and safety.

8.4 Regular Maintenance for Compliance

Perform routine inspections of detectors, sensors, and wiring to ensure optimal functionality. Test all output circuits and verify proper operation. Update software and firmware regularly to maintain compliance with safety standards. Replace worn or damaged components promptly. Keep detailed maintenance records for audit purposes. Always follow the manufacturer’s guidelines for scheduled upkeep.

Resources and Downloads

Access official Notifier AFP-200 manuals, including installation, instruction, and programming guides, in PDF format. Download software tools and firmware updates from authorized sources for optimal performance and compliance.

9.1 Accessing Manuals Online

Official Notifier AFP-200 manuals are available for free online viewing or downloading in PDF format. Visit authorized websites or the Notifier Fire-Lite portal to access installation, instruction, and programming guides. Ensure compliance by using genuine documents for accurate system setup and maintenance. Always verify the source for authenticity and the latest updates.

9.2 Software and Tools for Programming

Notifier provides specific software tools for programming the AFP-200, such as Notifier PK-1 release 2.0 or terminal emulation software. These tools enable advanced configuration and customization of the system. They are available for download through official Notifier resources or authorized distributors, ensuring compatibility and optimal performance for tailored fire safety solutions.

9.3 Technical Support and Contact Information

Notifier offers comprehensive technical support for the AFP-200 system. Users can access assistance via phone, email, or through the official Notifier website. Additional resources include downloadable materials and online support portals. For direct inquiries, contact Notifier at their headquarters or authorized distributors for prompt and reliable assistance with installation, programming, or troubleshooting needs.

Written by