The Trilogy Evo Ventilator is a versatile, portable device designed for both invasive and non-invasive ventilation, suitable for pediatric to adult patients. It offers advanced features, ease of use, and compatibility with various accessories, making it ideal for home care and portable use. Its design ensures reliable performance and patient comfort.
Overview of the Trilogy Evo Universal Ventilator
The Trilogy Evo Universal Ventilator is a portable, electronically controlled pneumatic system designed for invasive and non-invasive ventilation. It supports pediatric, infant, and adult patients weighing 2.5 kg or more. With an integrated air compressing system, it ensures reliable performance in various care settings, including homes and hospitals. Its compact design, detachable battery, and advanced technology make it versatile for both stationary and portable use, catering to diverse patient needs and operational requirements.
Intended Use and Target Patient Population
The Trilogy Evo Universal Ventilator is designed for both invasive and non-invasive positive pressure ventilation. It is intended for pediatric, infant, and adult patients weighing 2.5 kg or more. Suitable for various care settings, including home, hospital, and portable use, the Trilogy Evo provides reliable ventilation support tailored to individual patient needs, ensuring comfort and effective therapy across different environments.
Key Features of the Trilogy Evo
The Trilogy Evo features a portable, lightweight design, supporting both invasive and non-invasive ventilation. It includes advanced technology for CO2 monitoring, multiple operational modes, and a detachable battery providing up to 7.5 hours of use, ensuring versatility and reliability in various care settings.
Design and Portability
The Trilogy Evo is designed with portability and ease of use in mind. Its lightweight and compact structure makes it ideal for both home care and portable use. The ventilator features a durable design with a user-friendly interface, ensuring easy navigation for caregivers. A detachable battery provides up to 7.5 hours of continuous operation, enhancing mobility for patients on the go. The device also comes with a travel bag and roll stand, further promoting convenience and versatility in various care settings. Its sleek design ensures minimal space occupation while maintaining robust functionality.
Performance and Operational Modes
The Trilogy Evo delivers reliable performance across various operational modes, supporting both invasive and non-invasive ventilation. It offers precise control of pressure and flow, ensuring tailored therapy for diverse patient needs. The device operates in AC, DC, and battery modes, providing flexibility in different care settings. Its advanced algorithms and real-time monitoring enhance therapy delivery, while the ActivePAP circuit allows for accurate CO2 monitoring. The ventilator’s robust performance ensures consistent support for pediatric to adult patients, making it suitable for both home and clinical environments.
Advanced Technology and Integration
The Trilogy Evo incorporates cutting-edge technology for enhanced patient care. It features advanced algorithms for precise ventilation control and seamless integration with external monitoring systems. The device supports CO2 monitoring via the ActivePAP circuit, enabling real-time tracking of exhaled carbon dioxide. Its user-friendly interface and connectivity options ensure easy data sharing and remote monitoring. These technologies work together to provide a comprehensive and adaptable ventilation solution, optimizing patient outcomes in various clinical and home care settings.
Setting Up and Preparing the Trilogy Evo
Setting up the Trilogy Evo involves unpacking and inventorying all components, connecting accessories, and performing pre-use checks. Ensure the exterior is cleaned with a lint-free cloth and detergent solution; Disconnect power before cleaning and avoid blocking air vents. Follow manual guidelines for charging the detachable battery and operating within specified environmental ranges.
Unpacking and Inventory of Components
When unpacking the Trilogy Evo, carefully inspect all components, including the ventilator unit, detachable battery, in-use case, and travel bag. Ensure the package contains the ActivePAP circuit, exhalation ports, and compatible patient interfaces. Verify the presence of accessories like the roll stand and circuit support arm. Check for any damage or missing items. Refer to the manual for a detailed list of included components. Ensure all parts are compatible and properly inventoried before initial use to guarantee safe and effective operation.
Connecting Accessories and Patient Interfaces
Connect approved accessories to the Trilogy Evo to ensure proper function. Attach the ActivePAP circuit and exhalation ports as per the manual. Secure the patient interface, such as masks or tubes, to the circuit support arm. Ensure all connections are tight to maintain ventilation integrity. Use only compatible components to avoid leaks or malfunctions. Refer to the accessories guide for a list of approved items. Properly connecting these elements ensures accurate CO2 monitoring and reliable ventilation support for the patient.
Pre-Use Checks and Safety Precautions
Before using the Trilogy Evo, ensure the device is clean and free from blockages. Disconnect it from power and detach all accessories. Use a lint-free cloth and liquid dishwashing detergent solution to clean the exterior weekly. Avoid harsh chemicals or abrasive materials. Always verify the integrity of circuits and exhalation ports. Check for proper ventilation by ensuring the cooling and intake air vents are not blocked. Use only approved accessories to maintain safety and function. Ensure the detachable battery is fully charged and securely attached for portable use. Follow all safety guidelines outlined in the manual to ensure reliable operation and patient safety.
Operating Modes and Configuration
The Trilogy Evo supports invasive and non-invasive ventilation modes, offering customizable settings for CPAP, BiPAP, and AVAP. It allows precise adjustment of parameters like pressure, flow, and breath rate, ensuring tailored therapy for diverse patient needs. The device also features an ActivePAP circuit for enhanced monitoring of exhaled CO2, enabling accurate therapy delivery and patient comfort.
Invasive vs. Non-Invasive Ventilation Settings
The Trilogy Evo accommodates both invasive and non-invasive ventilation, catering to diverse patient needs. Invasive settings require specific configurations and accessories, ensuring precise control for critically ill patients. Non-invasive modes, such as CPAP or BiPAP, are ideal for patients with less severe respiratory conditions. The device supports a wide range of therapies, from pediatric to adult care, with adjustable settings to meet individual requirements. Proper configuration ensures safe and effective ventilation, addressing both clinical and home care scenarios.
Adjusting Ventilator Parameters
Adjusting Trilogy Evo parameters ensures personalized therapy for patients. Tidal volume, respiratory rate, and pressure levels can be tailored to individual needs. The device allows precise adjustments, guided by clinical guidelines, to optimize ventilation. Real-time monitoring enables healthcare providers to fine-tune settings for improved patient outcomes. Proper parameter adjustment is critical for effective therapy, ensuring comfort and safety. Always refer to the manual for specific instructions to avoid errors and maintain optimal performance.
Using the ActivePAP Circuit and Monitoring CO2
The Trilogy Evo’s ActivePAP circuit enables precise ventilation therapy by maintaining consistent pressure and flow. When using this circuit, CO2 monitoring is essential to measure exhaled carbon dioxide levels, ensuring therapy effectiveness. The device complies with ISO 80601-2-55 standards for accurate CO2 measurement. Intentional leaks may cause discrepancies in exhaled volume and CO2 values, so proper circuit setup is crucial. Regular monitoring helps healthcare providers adjust settings for optimal patient outcomes and safety. Always follow the manual for detailed procedures.
Accessories and Compatibility
The Trilogy Evo is compatible with a range of approved accessories, including patient interfaces, circuits, and exhalation ports. A detachable battery provides up to 7.5 hours of use, while the travel bag and in-use case offer convenient portability. Ensure all accessories are compatible to maintain safety and performance.
Approved Accessories for Safe Use
The Trilogy Evo must only be used with accessories specifically approved for this device. These include patient interfaces, circuits, exhalation ports, and cables. The detachable battery (part number 1127889) provides up to 7.5 hours of operation, while the travel bag (part number 1134428) and in-use case (part number 1133930) ensure portability. Using unapproved accessories can compromise safety and performance. Always verify compatibility through the official Trilogy Evo accessories guide or manufacturer’s instructions to ensure compliance with safety standards.
Compatible Circuits and Exhalation Ports
The Trilogy Evo supports a range of compatible circuits, including single-limb and dual-limb options, designed to meet specific patient needs. Exhalation ports must be selected based on the patient’s requirements and ventilation mode. The ActivePAP circuit is a key accessory, enabling precise pressure delivery and CO2 monitoring. Always ensure circuits and ports are approved for use with the Trilogy Evo to maintain safety and performance. Using incompatible components can lead to device malfunction or inaccurate therapy delivery, emphasizing the importance of adhering to manufacturer guidelines.
Detachable Battery and Power Options
The Trilogy Evo features a detachable battery, providing up to 7.5 hours of continuous use under normal conditions. This battery is hot-swappable, allowing for uninterrupted therapy during replacement. The device also supports AC and DC power modes, enhancing versatility for home or travel use. A dedicated in-use case and travel bag are available to protect the ventilator and its components. These power options ensure reliable operation across various settings, making the Trilogy Evo ideal for both stationary and portable applications while maintaining patient care continuity.
Maintenance and Cleaning
Regularly clean the Trilogy Evo’s exterior with a lint-free cloth and soft-bristle brush using a diluted dishwashing detergent solution. Ensure the device is off and disconnected from power before cleaning.
Cleaning the Exterior and Accessories
To maintain the Trilogy Evo Ventilator, clean the exterior weekly using a lint-free cloth and soft-bristle brush with a diluted dishwashing detergent solution. Disconnect power and remove all accessories before cleaning. Avoid harsh chemicals or abrasive materials that may damage the surface. Use a clean, damp cloth to wipe down the device, ensuring no moisture enters vents or ports. Allow the device to air dry completely before reconnecting accessories or powering on. Regular cleaning prevents dust buildup and ensures optimal performance. Refer to the manual for detailed cleaning instructions and compatibility of cleaning agents.
Servicing and Replacing Parts
Regular servicing of the Trilogy Evo Ventilator is essential for optimal performance. Replace parts like exhalation valves, bacterial filters, and flow sensors as recommended in the manual. Inspect accessories and components for wear and tear, replacing them promptly to ensure safety and accuracy. Always use Philips-approved parts to maintain warranty and safety standards. After replacing any part, perform calibration if required. Routine maintenance prevents mechanical failures and ensures accurate ventilation delivery; Refer to the manual for specific guidelines on servicing and replacement procedures.
Troubleshooting and Error Management
Identify common errors like low battery or blocked sensors. Refer to alarm codes in the manual for specific solutions. Contact support for unresolved issues.
Understanding Alarms and Error Codes
The Trilogy Evo ventilator features a comprehensive alarm system to ensure patient safety. Alarms are triggered by conditions like low battery, high pressure, or obstructed airflow. Error codes, such as those for sensor malfunctions or circuit issues, provide specific diagnostics. Refer to the user manual for a detailed list of codes and their meanings. Addressing alarms promptly is crucial to maintain ventilation support. Always perform pre-use checks and ensure proper accessory connections to minimize errors. If unresolved, contact Philips Respironics support for assistance.
Resolving Common Issues
Common issues with the Trilogy Evo can often be resolved by checking connections and ensuring proper setup. For low battery, recharge or replace it. If alarms sound, check for kinks in tubing or blockages. Ensure all accessories are compatible and properly attached. Clean the exterior regularly to maintain functionality. If error codes appear, consult the user manual or contact Philips Respironics support. Always use authorized parts to avoid malfunctions. Regular maintenance and adherence to guidelines can prevent most issues, ensuring reliable performance.
The Trilogy Evo Ventilator is a versatile, portable device offering advanced ventilation solutions for various patient needs, ensuring reliable and effective respiratory support in diverse care settings.
The Trilogy Evo Ventilator is designed for both invasive and non-invasive ventilation, catering to pediatric, adult, and infant patients weighing 2.5 kg or more. It offers portable, universal ventilation solutions, ideal for home care, hospitals, or travel. Key features include advanced modes like CPAP, BiPAP, and AVAPS, along with CO2 monitoring via the ActivePAP circuit. The device supports up to 7.5 hours of operation with its detachable battery and is compatible with a range of approved accessories. Regular maintenance, including cleaning and part replacements, ensures optimal performance and patient safety.
Final Tips for Effective Use
Always follow the Trilogy Evo manual for setup, operation, and maintenance. Use only approved accessories to ensure compatibility and safety. Regularly clean the exterior and accessories to prevent contamination. Ensure proper patient interface connections and monitor ventilation settings closely. Keep the detachable battery charged for uninterrupted use. Train caregivers on alarm troubleshooting and error management. Refer to instructional videos for visual guidance on configuring accessories and resolving common issues. Adhere to maintenance schedules to uphold device performance and patient safety.